Chromium Code Reviews
chromiumcodereview-hr@appspot.gserviceaccount.com (chromiumcodereview-hr) | Please choose your nickname with Settings | Help | Chromium Project | Gerrit Changes | Sign out
(776)

Side by Side Diff: net/quic/core/quic_flags_list.h

Issue 2825093002: Continue sending at the max bandwidth measured in the last two rounds for another SRTT. Protected … (Closed)
Patch Set: Created 3 years, 8 months ago
Use n/p to move between diff chunks; N/P to move between comments. Draft comments are only viewable by you.
Jump to:
View unified diff | Download patch
« no previous file with comments | « net/quic/core/congestion_control/bbr_sender_test.cc ('k') | no next file » | no next file with comments »
Toggle Intra-line Diffs ('i') | Expand Comments ('e') | Collapse Comments ('c') | Show Comments Hide Comments ('s')
OLDNEW
1 // Copyright 2014 The Chromium Authors. All rights reserved. 1 // Copyright 2014 The Chromium Authors. All rights reserved.
2 // Use of this source code is governed by a BSD-style license that can be 2 // Use of this source code is governed by a BSD-style license that can be
3 // found in the LICENSE file. 3 // found in the LICENSE file.
4 4
5 // This file intentionally does not have header guards, it's included 5 // This file intentionally does not have header guards, it's included
6 // inside a macro to generate values. 6 // inside a macro to generate values.
7 7
8 // This file contains the list of QUIC protocol flags. 8 // This file contains the list of QUIC protocol flags.
9 9
10 // If true, QUIC BBR congestion control may be enabled via Finch and/or via QUIC 10 // If true, QUIC BBR congestion control may be enabled via Finch and/or via QUIC
(...skipping 194 matching lines...) Expand 10 before | Expand all | Expand 10 after
205 205
206 // If true, on server side, 8-byte connection ID in public header is read and 206 // If true, on server side, 8-byte connection ID in public header is read and
207 // written in big endian. 207 // written in big endian.
208 QUIC_FLAG(bool, 208 QUIC_FLAG(bool,
209 FLAGS_quic_restart_flag_quic_big_endian_connection_id_server, 209 FLAGS_quic_restart_flag_quic_big_endian_connection_id_server,
210 false) 210 false)
211 211
212 // Simplify QUIC\'s adaptive time loss detection to measure the necessary 212 // Simplify QUIC\'s adaptive time loss detection to measure the necessary
213 // reordering window for every spurious retransmit. 213 // reordering window for every spurious retransmit.
214 QUIC_FLAG(bool, FLAGS_quic_reloadable_flag_quic_fix_adaptive_time_loss, false) 214 QUIC_FLAG(bool, FLAGS_quic_reloadable_flag_quic_fix_adaptive_time_loss, false)
215
216 // In QUIC BBR, keep sending at the max bandwidth observed in the previous 2
217 // RTTs for another SRTT.
218 QUIC_FLAG(bool,
219 FLAGS_quic_reloadable_flag_quic_bbr_keep_sending_at_recent_rate,
220 false)
OLDNEW
« no previous file with comments | « net/quic/core/congestion_control/bbr_sender_test.cc ('k') | no next file » | no next file with comments »

Powered by Google App Engine
This is Rietveld 408576698