Descriptionsimplify nanobench --quiet / -q output
This tries to cut things down to the very minimum you might want to know:
$ out/Release/nanobench --match nytimes --config 8888 gpu -q
Timer overhead: 29.6ns
! -> high variance, ? -> moderate variance
micros bench
2479.05 ! desk_nytimes.skp_1_mpd 8888
1313.92 desk_nytimes.skp_1_mpd gpu
3617.65 desk_nytimes.skp_1 8888
1158.34 desk_nytimes.skp_1 gpu
1368.99 ! keymobi_nytimes_com_.skp_1_mpd 8888
393.40 keymobi_nytimes_com_.skp_1_mpd gpu
1179.68 ! keymobi_nytimes_com_.skp_1 8888
342.74 keymobi_nytimes_com_.skp_1 gpu
All times are printed in microseconds, and high variance runs are marked.
BUG=skia:
Committed: https://skia.googlesource.com/skia/+/66cfcffd5d0a430f00bf0e36bedb088a25957183
Patch Set 1 #
Messages