| Index: third_party/buildbot_7_12/buildbot/scripts/reconfig.py
|
| diff --git a/third_party/buildbot_7_12/buildbot/scripts/reconfig.py b/third_party/buildbot_7_12/buildbot/scripts/reconfig.py
|
| deleted file mode 100644
|
| index 104214b51651820f40492a46eee603013b415d94..0000000000000000000000000000000000000000
|
| --- a/third_party/buildbot_7_12/buildbot/scripts/reconfig.py
|
| +++ /dev/null
|
| @@ -1,69 +0,0 @@
|
| -
|
| -import os, signal, platform
|
| -from twisted.internet import reactor
|
| -
|
| -from buildbot.scripts.logwatcher import LogWatcher, BuildmasterTimeoutError, \
|
| - ReconfigError
|
| -
|
| -class Reconfigurator:
|
| - def run(self, config):
|
| - # Returns "Microsoft" for Vista and "Windows" for other versions
|
| - if platform.system() in ("Windows", "Microsoft"):
|
| - print "Reconfig (through SIGHUP) is not supported on Windows."
|
| - print "The 'buildbot debugclient' tool can trigger a reconfig"
|
| - print "remotely, but requires Gtk+ libraries to run."
|
| - return
|
| -
|
| - basedir = config['basedir']
|
| - quiet = config['quiet']
|
| - os.chdir(basedir)
|
| - f = open("twistd.pid", "rt")
|
| - self.pid = int(f.read().strip())
|
| - if quiet:
|
| - os.kill(self.pid, signal.SIGHUP)
|
| - return
|
| -
|
| - # keep reading twistd.log. Display all messages between "loading
|
| - # configuration from ..." and "configuration update complete" or
|
| - # "I will keep using the previous config file instead.", or until
|
| - # 10 seconds have elapsed.
|
| -
|
| - self.sent_signal = False
|
| - lw = LogWatcher("twistd.log")
|
| - d = lw.start()
|
| - d.addCallbacks(self.success, self.failure)
|
| - reactor.callLater(0.2, self.sighup)
|
| - reactor.run()
|
| -
|
| - def sighup(self):
|
| - if self.sent_signal:
|
| - return
|
| - print "sending SIGHUP to process %d" % self.pid
|
| - self.sent_signal = True
|
| - os.kill(self.pid, signal.SIGHUP)
|
| -
|
| - def success(self, res):
|
| - print """
|
| -Reconfiguration appears to have completed successfully.
|
| -"""
|
| - reactor.stop()
|
| -
|
| - def failure(self, why):
|
| - if why.check(BuildmasterTimeoutError):
|
| - print "Never saw reconfiguration finish."
|
| - elif why.check(ReconfigError):
|
| - print """
|
| -Reconfiguration failed. Please inspect the master.cfg file for errors,
|
| -correct them, then try 'buildbot reconfig' again.
|
| -"""
|
| - elif why.check(IOError):
|
| - # we were probably unable to open the file in the first place
|
| - self.sighup()
|
| - else:
|
| - print "Error while following twistd.log: %s" % why
|
| - reactor.stop()
|
| -
|
| -def reconfig(config):
|
| - r = Reconfigurator()
|
| - r.run(config)
|
| -
|
|
|