Index: build/android/pylib/instrumentation/test_runner.py |
diff --git a/build/android/pylib/instrumentation/test_runner.py b/build/android/pylib/instrumentation/test_runner.py |
index d1c5a4d6bc396e5a83523ca705b4cee57101154d..174f4efb5e2e12c61fa8f3823622c4aa33df420a 100644 |
--- a/build/android/pylib/instrumentation/test_runner.py |
+++ b/build/android/pylib/instrumentation/test_runner.py |
@@ -11,6 +11,7 @@ import sys |
import time |
from pylib import constants |
+from pylib import device_settings |
from pylib import flag_changer |
from pylib import valgrind_tools |
from pylib.base import base_test_result |
@@ -98,8 +99,10 @@ class TestRunner(base_test_runner.BaseTestRunner): |
if self.device.SetJavaAsserts(self.options.set_asserts): |
# TODO(jbudorick) How to best do shell restart after the |
# android_commands refactor? |
+ device_settings.SetLockScreenSettings(self.device) |
jbudorick
2015/05/29 13:06:15
Why would we set the lock screen settings here?
JungJik
2015/06/01 14:44:51
When I execute the instrumentation,
if the lock sc
jbudorick
2015/06/01 14:50:56
This isn't in the scope of the test runner. We han
JungJik
2015/06/02 16:09:45
thanks for your help. I've checked the file.
I've
|
self.device.RunShellCommand('stop') |
self.device.RunShellCommand('start') |
+ self.device.WaitUntilFullyBooted() |
# We give different default value to launch HTTP server based on shard index |
# because it may have race condition when multiple processes are trying to |